Tag Archive for: installation manual

Tips for Properly Installing S-Type Load Cells
S-type load cell installation success hinges on protecting the sensor's gauged area from extraneous mechanical forces during setup. Interface provides installation tips, a setup video, and instructions. By ensuring that all tightening torque is applied to a single end, maintaining a minimum thread-depth engagement of one diameter, locking the threads to a shoulder or jam nut, and using high-grade hardware for loads exceeding the sensor’s capacity, you eliminate the leading causes of failure. Proper installation protects the load cell's calibration integrity, longevity, and safety across applications.

Typical Installation of LowProfile Compression-Only Load Cells
Interface offers detailed LowProfile installation best practices for Compression-Only Load Cell models 1101, 1201, and 3201, along with a step-by-step video on installing these force measurement sensors that are used in aerospace, medical, energy, industrial, and general fatigue testing applications. Get the full installation guide and tips for the most popular low-profile load cells.